Roofing panel designed to reproduced the shape of clay tiles consisting of a a profiled metal weather liner; an EPS insulation layer and an internal liner of lightly fluted metal sheet.
The EPS insulation is shaped to form a ventilation chamber between the profiles that promotes an effective roof ventilation.
TEGOSTIL VENTILATO is most suitable for civil and agricultural destinations of use, as well as for cost-effective commercial and industrial roofing applications.
15% minimum gradient subject to local building regulations


| Parameters | Dimensions | Tolerances |
| Width | 1060 mm - cover width 1000 mm | ± 5 mm |
| Length | from 1150 to 7100 mm | L ≤ 3000 mm ± 5 mm L > 3000 mm ± 10 mm |
| Overall Height | 90-110-150 mm | ± 2 mm |
| Profile height | 29 mm | ± 2 mm |
| Profile pace | 350 mm | ± 5 mm |
| Profile depth | 13 mm | ± 2 mm |
| Deviation of perpendicularity | - | 0.60 % |
| Average cross section area of the ventilation channels | 165 cm²/m per linear meter of cross section | - |
* for other lengths that are not multiples of the tile pattern, please contact our Technical Dept.
| Test | Value | Norms |
| Resistance to external fire | Bʀᴏᴏғ(t3) | UNI EN 13501-5 |
| Reaction to Fire | class E |
| Resistance to water vapour | μ = 30-70 |
| Compressive strength at 10% crush rate CS (10) | ≥ 100 Kpa |
| Value | Norms | |
| Noise abatement value | Rw = 25 dB | UNI EN ISO 10140-2 UNI EN ISO 717-1 |
| Sound generated by rainfall | LIA = 55dB (A) | UNI EN ISO 10140-1 UNI EN ISO 10140-5 |
| Material | Nominal thickness of the weather liner metal sheet (mm) |
Thickness of EPS insulation with graphite euroclass E SE/hT (mm) |
Thermal conductivity λD = 0.030 W/mK (U = W/m²K) |
Weight of the panel Tegostil Ventilato with 0,4mm internal metal liner (kg/m²) |
Uniformly distributed imposed load kg/m2, including own weight * (kg/m²) |
||
| Span (m) |
|||||||
| 0.70 | 1.05 | 1.40 | |||||
| Aluminium | 0,7 | 50/90 | 0,60 | 7,68 | 215 | 200 | 130 |
| Aluminium | 0,7 | 70/110 | 0,43 | 8,08 | 218 | 203 | 133 |
| Aluminium | 0,7 | 110/150 | 0,27 | 8,88 | 228 | 213 | 141 |
| Coated steel Aluzinc Stainless steel |
0,5 | 50/90 | 0,60 | 10,21 | 300 | 270 | 215 |
| Coated steel Aluzinc Stainless steel |
0,5 | 70/110 | 0,43 | 10,61 | 305 | 275 | 220 |
| Coated steel Aluzinc Stainless steel |
0,5 | 110/150 | 0,27 | 11,41 | 315 | 285 | 230 |
| Coated steel Aluzinc Stainless steel |
0,6 | 50/90 | 0,60 | 11,13 | 320 | 290 | 230 |
| Coated steel Aluzinc Stainless steel |
0,6 | 70/110 | 0,43 | 11,53 | 325 | 295 | 235 |
| Coated steel Aluzinc Stainless steel |
0,6 | 110/150 | 0,27 | 12,33 | 335 | 305 | 245 |
| Copper | 0,6 | 50/90 | 0,60 | 11,83 | 240 | 210 | 135 |
| Copper | 0,6 | 70/110 | 0,43 | 12,23 | 244 | 214 | 139 |
| Copper | 0,6 | 110/150 | 0,27 | 13,03 | 254 | 225 | 150 |
N.B. Listed values are indicative and as tested in our laboratory. Static calculations are the responsibility of the Designer / Main Contractor. Alternative insulation thickness available.
* Calculated with a deflection value ≤ 1/200 L